Home / Blog / Research & Case Studies / Replacing Legacy Actiwatch Systems Without Breaking Longitudinal Research Protocols

Replacing Legacy Actiwatch Systems Without Breaking Longitudinal Research Protocols

actiwatch migration research

For sleep laboratories and academic research groups, actiwatch replacement sleep research is not simply a matter of buying a new wrist device. Philips ended support for the Actiwatch product family after discontinuing the business that produced its actigraphy products, which means established protocols now face questions about legacy files, scoring methods, software access, and the comparability of new recordings with historical datasets. Those questions should be resolved before a replacement device enters routine use.

Our Actiwatch Migration Guide is built around that continuity problem. It describes a workflow for converting legacy files, retaining familiar sleep-scoring approaches, exporting new recordings in an Actiware-style CSV layout, and validating the transition with parallel wear. For teams looking for a Philips Actiwatch alternative, this is a stronger starting point than comparing battery life or purchase price in isolation.

The goal of a migration is not to pretend that different manufacturers generate identical activity counts. They do not. The aim is to document what can remain consistent, quantify what changes, and build a defensible bridge between old and new study phases.

Why Hardware Discontinuation Creates a Data-Continuity Problem

Philips stated that support for Actiware, Actiwatch 2, Actiwatch PRO, and Actiwatch Plus ended on December 29, 2023. The official Philips end-of-support notice matters because the risk is broader than hardware availability. A laboratory may have years of archived recordings, analysis scripts built around Actiware exports, published methods that cite a particular algorithm, and staff trained on a workflow that can no longer be assumed to receive future support.

If a research team treats replacement as a procurement task only, the result can be two partially disconnected datasets. Historical participants were measured with one device family and processed in one software ecosystem, while future participants are measured and scored differently. Reviewers may then ask whether a reported change reflects biology, intervention, season, or the measurement transition itself.

That is why a migration plan should inventory more than the number of devices in a cabinet. Teams should record file formats, epoch lengths, scoring algorithms, export structures, custom scripts, event-marker conventions, diary fields, and any population-specific scoring decisions. This inventory defines which parts of the original protocol must be preserved or explicitly revalidated.

legacy actigraphy analysis

Preserve Legacy Data Before Choosing New Hardware

The first technical question should be whether the old archive remains usable. ActStudio includes a converter between Actiwatch and Condor data formats, allowing legacy recordings to be opened and reprocessed rather than left in an unsupported environment. It also implements the Actiware sleep-scoring method described in Philips documentation and can export Condor recordings in the same CSV layout used by Actiware.

Those capabilities help preserve parts of the workflow, but they do not erase device differences. Activity counts are device-specific because accelerometers, sampling, filtering, and proprietary processing differ. A shared scoring algorithm can reduce one source of variation, yet it does not make raw or processed activity from different hardware inherently interchangeable. A responsible actigraphy device comparison therefore separates algorithm continuity from hardware equivalence.

Teams should also preserve an untouched copy of the historical archive before any batch conversion. Converted files can then be checked against a small validation set with known results, and the laboratory can document software version, converter version, timezone handling, epoch length, and any metadata fields that change during import. That record becomes part of the methods trail and reduces the risk that a future analyst cannot explain how legacy data entered the new system.

Clinical guidance also supports this cautious approach. The AASM clinical practice guideline for actigraphy treats actigraphy as a method that must be used for defined indications and interpreted within an appropriate clinical context. When a long-running research protocol changes hardware, the same principle applies: the measurement method should be documented, justified, and validated for the intended outcome rather than assumed to be identical because both devices are called actigraphs.

research actigraphy devices

Compare Replacement Devices on More Than Battery Life

Recording duration matters, especially when a study spans weeks or when devices are shipped to participants, but it is only one axis. Research teams should compare accelerometer characteristics, light sensing, temperature channels, wear-time detection, memory, event marking, communication method, raw-data access, export formats, and the availability of maintained analysis software. The priority of each feature depends on the protocol.

Participant workflow belongs on the same comparison sheet. A replacement may technically satisfy the sensor requirements yet introduce a different charging routine, a heavier device, a more complex event button, or a transfer step that is unrealistic for a decentralized cohort. These operational differences can affect adherence, so procurement teams should test the full participant journey before committing a large study to new hardware.

Light measurement deserves separate scrutiny for teams that previously used Actiwatch Spectrum. Modern circadian research increasingly reports melanopic as well as photopic quantities, and the CIE Position Statement on Integrative Lighting recommends use of the CIE S 026 system for characterizing ipRGC-influenced effects of light. A single broadband lux channel cannot provide the same information as a characterized multi-channel spectral system.

Independent 2026 NIH research comparing wearable light sensors found substantial differences in detection range, accuracy, and inter-device variability. In that peer-reviewed wearable light-sensor evaluation, ActLumus showed a 2 to 100,000 lux detection range under the tested conditions and the lowest inter-device variability among the four evaluated systems. For a migration involving circadian-light outcomes, independent characterization of this kind is more informative than a marketing statement that a device includes a light sensor.

Use a Controlled Migration Protocol

A practical migration begins with a small set of historical files. Convert them, confirm epoch settings, reproduce the scoring method used in prior analyses, and compare outputs with archived results. Any difference should be investigated before the full archive is processed. This step tests the software bridge independently of the new hardware.

Next, run a parallel-wear period where feasible. A subsample can wear the legacy device and the replacement during the same days so the team can quantify offsets in its own population and setting. For protocols that add light outcomes, the 2026 NIH wearable light-sensor evaluation is an example of the independent characterization that can inform what should be checked during transition. The purpose is not to force two devices to agree perfectly. It is to characterize the transition well enough that future analyses can account for a device change, stratify periods when necessary, or establish a documented correction strategy.

Finally, freeze the migration decisions in the protocol. Record which scoring algorithm is used, how legacy files were converted, how new data are exported, how device effects were assessed, and whether additional variables such as melanopic EDI are treated as new outcomes rather than retroactively compared with data that could not measure them. This documentation makes the transition reviewable and reproducible.

For multi-site programs, the transition should be coordinated centrally. Sites should receive the same firmware, configuration template, scoring settings, training materials, and migration checklist. If some sites continue using legacy devices while others move earlier, the analysis plan should track device family by participant and visit. Treating the hardware change as a study variable is more defensible than allowing it to disappear into local operating differences.

actiwatch data continuity

A Research-Focused Path Beyond Discontinued Actiwatch Hardware

The strongest research-grade actigraph replacement strategy is one that separates what can be preserved from what must be revalidated. Legacy files and familiar scoring may be carried forward, while hardware differences should be quantified rather than hidden.

At Condor Instruments, we designed ActStudio to support legacy Actiwatch conversion and current ActTrust and ActLumus workflows. That gives research teams an actigraph data logger ecosystem in which historical recordings, new measurements, and reproducible exports can be managed within a maintained analysis path. Teams can also review ActStudio capabilities before defining their migration method.

For help mapping an existing Actiwatch archive and protocol to a new recording workflow, contact our team.

Three Questions Before Migrating an Actiwatch Study

Why are research teams upgrading from traditional Actiwatch hardware to modern actigraphs?

The immediate reason is product discontinuation and the end of support, but the research reason is continuity. Laboratories need hardware they can procure and maintain for future cohorts while preserving access to historical recordings and established analysis methods. A newer device may also add capabilities that were not available in the original system, such as more detailed light measurement or dedicated wear-time detection. Those additions should be treated as protocol changes and documented accordingly.

How does extended battery life affect long-term clinical and academic sleep studies?

Longer recording capacity can reduce mid-study charging, device returns, and gaps in protocols that run for weeks. It becomes especially important in remote cohorts, field research, seasonal studies, or designs where participants cannot easily return to the laboratory. Battery figures should always be considered together with memory, epoch length, transfer method, and the real deployment schedule because those factors determine whether the advertised duration can actually support the study.

What device specifications matter most when transitioning legacy sleep study protocols?

The critical specifications are the ones tied to existing outcomes and workflow: accelerometer processing, recording duration, sensor set, light measurement, wear-time detection, event marking, file conversion, scoring methods, raw-data access, export structure, and software support. A replacement that matches a familiar form factor but changes the analytical pipeline may create more methodological disruption than a device that looks different but provides a documented path for preserving data and scoring continuity.

Related content

Research Ready Light Data - Infograph

Research Ready Light Data – Infograph

This Condor Instruments infographic showcases how ActLumus supports reliable circadian research through accurate light exposure tracking, synchronized wearable data, research

Singapore Researcher Highlights ActLumus in Study on Light Exposure and Myopia

Discover how NUS researchers use ActLumus wearable light sensors in the LightSPAN Project to investigate light exposure and myopia progression
Replace Legacy Actiwatch Systems - Infograph

Replace Legacy Actiwatch Systems – Infograph

This Condor Instruments infographic highlights key considerations for transitioning from Actiwatch devices, including preserving historical data, documenting workflows, validating conversions,

Subscribe to receive news